Octet No. |
Contents |
10
|
Parameter category (see Code
table 4.1)
|
11
|
Parameter number (see Code table
4.2)
|
12-13
|
Aerosol Type (see
Code table 4.233)
|
14
|
Type of interval for first and second sizes (see
Code table 4.91)
|
15
|
Scale factor of first size
|
16-19
|
Scale value of first size in meters
|
20
|
Scale factor of second size
|
21-24
|
Scale value of second size in meters
|
25 |
Type of generating process (see
Code table 4.3)
|
26 |
Background generating process identifier (defined by originating centre)
|
27 |
Analysis or forecast generating process identifier
(see Code ON388 Table A)
|
28-29
|
Hours of observational data cutoff after reference time (see Note 1)
|
30 |
Minutes of observational data cutoff after reference time
|
31 | Indicator of unit of time range
(see Code table 4.4)
|
32-35 |
Forecast time in units defined by octet 31 |
36
|
Type of first fixed surface (see Code table 4.5)
|
37 |
Scale factor of first fixed surface |
38-41 |
Scaled value of first fixed surface
|
42 |
Type of second fixed surface (see Code table 4.5)
|
43 |
Scale factor of second fixed surface
|
44-47 |
Scaled value of second fixed surface
|