Octet No. | Contents |
---|---|
10 |
Parameter category (see Code Table 4.1) |
11 |
Parameter number (see Code Table 4.2) |
12 |
Type of generating process (see
Code Table 4.3) |
13 |
Background generating process
identifier (defined by originating centre) |
14 |
Analysis or forecast generating process identifier
(see Code ON388 Table A) |
15-16 | Hours of observational data
cutoff after reference time (see Note 1) |
17 |
Minutes of observational data
cutoff after reference time |
18 |
Indicator of unit of time range
(see Code Table 4.4) |
19-22 |
Forecast time in units defined
by octet 18 |
23-26 |
Total number of data values
missing in the statistical process 27-38 Specification of the outermost (or only) time range over which statistical processing is done |
27 |
Statistical process used to
calculate the processed field from the field at each time increment
during the time range (see Code Table
4.10) |
28 |
Type of time increment between
successive fields used in the statistical processing (see Code Table 4.11) |
29 |
Indicator of unit of time range
over which statistical processing (see Code Table 4.4) |
30-33 |
Length of the time range over
which statistical processing is done, in units defined by the previous
octet |
34 |
Indicator of unit of time for
the increment between the successive fields used (see Code Table 4.4) |
35-38 |
Time increment between
successive fields, in units defined by the previous octet (see Note 2) |
Notes:
(1) Hours greater than 65534 will be coded as 65534. |