Octet No. | Contents |
---|---|
10 |
Parameter category (see Code
Table 4.1) |
11 |
Parameter number (see Code Table
4.2) |
12 |
Type of generating process (see
Code Table 4.3) |
13 |
Background generating process
identifier (defined by originating centre) |
14 |
Forecast generating process identifier
(see Code ON388 Table A) |
15-16 |
Hours after reference time data
cutoff (see Note 1) |
17 |
Minutes after reference time
data cutoff |
18 |
Indicator of unit of time range
(see Code Table 4.4) |
19-22 |
Forecast time in units defined
by previous octet (see Note 2) |
23 |
Type of first fixed surface (see
Code Table 4.5) |
24 |
Scale factor of first fixed surface |
25-28 |
Scaled value of first fixed
surface |
29 |
Type of second fixed surfaced
(see Code Table 4.5) |
30 |
Scale factor of second fixed
surface |
31-34 |
Scaled value of second fixed
surfaces |
35 |
Percentile value (from 100% to
0%) |
36-37 |
Year of end of overall time
interval |
38 |
Month of end of overall time
interval |
39 |
Day of end of overall time
overall time interval |
40 |
Hour of end of overall time
interval |
41 |
Minute of end overall time interval |
42 |
Second of end of overall
time interval |
43 |
n ― number of time ranges specifications describing the time intervals used to calculate the statistically-processed field |
44-47 |
Total number of data values missing in the statistical process |
48 - 59 Specification of the outermost (or only) time
range over which statistical processing is done |
|
48 |
Statistical process used to
calculate the processed field from the field at each time increment
during the time range (see Code Table 4.10) |
49 | Type of time increment between successive fields used in the statistical processing (see Code Table 4.11) |
50 | Indicator of unit of time range
over which statistical processing is done (see Code Table 4.4) |
51-54 |
Length of the time range over
which statistical processing is done, in units defined by the previous
octet |
55 |
Indicator of unit of time for
the increment between the successive fields used (see Code Table 4.4) |
56-59 |
Time increment between successive fields, in units defined by the previous octet (see Note 3) |
60-nn These octets are included only if n>1, where nn = 47 + 12 x n | |
60-71 |
As octets 48-59, next innermost
step of processing |
72-nn |
Additional time range
specifications, included in accordance with the value of n,
Contents as octets 48 to 59, repeated as necessary. |
Notes:
(1) Hours greater than 65534 will be coded as 65534. |