NCEP Home > NCEP Central Operations > Data Management and Quality Assessment Branch > Quality Assessment Project > Monthly Raob Data Reports of Manual Quality Control > Monthly Raob Data Report
Monthly Raob Data Manual QC Report for Jul. 2021
Printer Friendly Version
Monthly Raob Data Manual QC Report for Jul. 2021
Previous Monthly Raob Data Reports of Manual Quality Control
SUBJECT: Monthly Raob Data Report of Manual Quality Control
The Raob Report for July, compiled from the Raob Recap statements in the
SDM logs, which does not necessarily include data that were rejected by
automated computer generated quality control, indicates the following:
(1) Reports from 35 U.S. stations (Blocks 72 and 74) were cited at least
once; 17 were cited at least twice; and 4 were cited at least three times.
Of those, the following were cited more than three times or had two or more no
reports:
STATION__ DEL BAS COR XRP EFL SHO TOTAL
72797/UIL 5 5
72469/DNR 4 4
72582/LKN 3 1 4
Station UIL reported ground equipment failures from the 7th through the 9th
of July. At stations DNR and LKN, all manual deletions were due to super-
adiabatic lapse rates.
(2) Reports from 47 stations in blocks 04, 70, 71, 76, 78 and 91 were cited
at least once; 30 were cited at least twice; and 23 were cited at least three
times. Of those, the following were cited more than three times or had two or
more no reports:
STATION__ DEL BAS COR XRP EFL SHO TOTAL
78384/GCM 28 28
70026/BRW 25 25
91334/TKK 1 17 1 19
70308/SNP 18 18
76405/LAP 14 14
76394/MTY 12 12
91348/PNI 2 8 10
71926/YBK 8 2 8*
70231/MCG 6 6
70200/OME 5 5
71119/WSE 5 5
76612/GDL 1 4 5
71082/YLT 3 1 1 4*
71867/YQD 4 4
71917/YEU 3 1 4
76256/GYM 1 3 4
Ground equipment failures were reported at various times throughout the month
at stations GCM, BRW, TKK, SNP, PNI, MCG, and OME. Station LAP reported flight
equipment failures in the early part of the month. At stations, WSE, YQD, YEU, and
GYM, all deletions were due to super-adiabatic lapse rates. On the other hand,
stations MTY, YBK, GDL, and YLT, deletions were due to issues with heights and
temperatures.
* The total differs from the sum of the itemized citations
because of multiple citations in the same raob(s).
Citation Codes Key:
DEL All or part of the raob was flagged for deletion.
BAS A baseline hgt/station press error was corrected or purged.
COR At least one correction other than baseline was made.
XRP Station sent no report at all when one was required.
EFL Equipment failure (codes 10142, 10144, 10158, etc.)
SHO Raob flight was short; ie, to less than 400 mb.
This and related reports are available on the Web at . . .
http://www.nco.ncep.noaa.gov/pmb/qap/raobqc/
|