W3FP12

The W3FP12 routine the product definition section according to the
           specifications set by wmo. using  o.n. 84 id's
           (1st 8 words) as the input data.

USAGE:    CALL W3FP12  (ID8, IFLAG, IDPDS, ICENT, ISCALE, IER)

   Input argument list:
      ID8      - FIRST 8 ID WORKDS (O.N.84) INTEGER*4
      ICENT    - CENTURY, 2 DIGITS, FOR 1991 IT IS 20.
      IFLAG    - INDICATION OF INCLUSION OR OMISSION OF GRID DEFINITION
                 AND/OR BIT MAP CODE        CHARACTER*1
      ISCALE   - 10 SCALER INTEGER*4

   Output argument list:      (INCLUDING WORK ARRAYS)
      IDPDS    - GRIB PRODUCT DEFINITION SECTION  CHARACTER*1 (28)
      IER      = 0 COMPLETED SMOOTHLY
               = 1 INDICATOR PARAMETER N.A. TO GRIB
               = 2 LEVEL INDICATOR N.A. TO GRIB
               = 3 TIME RANGE N.A. TO GRIB NOTATION
               = 4 LAYERS OR LEVELS N.A. TO GRIB

 
W3lib.tar Library contains Fortran 90 decoder/encoder routines for GRIB edition 1. (Fortran90)