INSTRUMENT

The INSTRUMENT routine monitors wall-clock times.

USAGE:    CALL INSTRUMENT(K,KALL,TTOT,TMIN,TMAX)

   Input argument list:
      K        - INTEGER POSITIVE SECTION NUMBER
                 OR MAXIMUM SECTION NUMBER IN THE FIRST INVOCATION
                 OR ZERO TO RESET ALL WALL-CLOCK STATISTICS
                 OR NEGATIVE SECTION NUMBER TO SKIP MONITORING
                 AND JUST RETURN STATISTICS.
 
   Output argument list:
      KALL     - INTEGER NUMBER OF TIMES SECTION IS CALLED
      TTOT     - REAL TOTAL SECONDS SPENT IN SECTION
      TMIN     - REAL MINIMUM SECONDS SPENT IN SECTION
      TMAX     - REAL MAXIMUM SECONDS SPENT IN SECTION

REMARKS:
        This subprogram should not be invoked from a multitasking region.
        normally, time spent inside this subprogram is not counted.
        wall-clock times are kept to the nearest millisecond.

 
W3lib.tar Library contains Fortran 90 decoder/encoder routines for GRIB edition 1. (Fortran90)