*  LOOKUP TABLE FOR FIXED PDS ELEMENTS FOR LDAS OUTPUT POST-PROCESSOR  *
*  ROUTINE.                                                            *
*  AUTHOR:  YOULONG XIA                                                *
*  DATE: SEPTEMBER 22,2013
*______________________________________________________________________*
*                                                                      *
*  IPDS ELEMENTS THAT CHANGE WITH TIME OR MODEL THAT ARE DEFINED IN    *
*  POST-PROCESSOR ROUTINE:                                             *
*                                                                      *
*  sec0(1)      0: Meteorological Products;1: Hydrologiical Products;  *
*               2: Land Surface Products                               *
*  ipdsnum      0: simultaneously; 8: accumulate or average            *
*  ipdstmp(24)  0: avergae; 1: accumulation (shown in code)            *
*  ipdstemllen  number of parameters in pdt template table             *
*               15: simultaneously; 30: accumulation or average        *
*  ipdstmp(1)   category selected from sec0(1) and grib2 table in Sec4 *
*               see Table 4.0 for ipdsnum=0 and Tbale 4.8 for ipdsnum=8*
*  ipdstmp(2)   Number for parameter (obtained from GRIB2 TAB          *
*  ipdstmp(10)  1: Ground surface;103: specified height level above    *
*               ground; 106:depth below land surface (m)               *        
*  pdstmp(11)  scaled factor of first fixed surface; 0:surface, 2:Soil*
*  ipdstmp(12)  Value of soil layer depth (0, 10, 40, 100)             *
*  ipdstmp(13)  1: Ground surface;103: specified height level above    *
*               ground; 106:depth below land surface (m) dor 2nd layer *
*  ipdstmp(14) scaled factor of 2nd fixed surface; 0:surface, 2:Soil   *
*  ipdstmp(15) Value of soil layer depth (0, 10, 40, 100, 200)         *
*  ipdstmp(24) 0: average; 1: accumulation                             *
*  idrstmp(3)   Decimal scale factor                                   *
*  THE ELEMENTS USED HERE THAT REMAIN FIXED (DO NOT VARY BY LDAS MODEL,*
*  TIME STEP, OR AMONG THE OUTPUT PARAMTERS) AND ARE DEFINED NOT IN    *
*  THE TABLE, BUT IN THE OUTPUT POST-PROCESSOR ROUTINE:                *
*                                                                      *
*  DETALIS CAN SEE                                                     *
*  http://www.nco.ncep.noaa.gov/pmb/docs/grib2/grib2_doc.shtml         *
*                                                                      *
************************************************************************
*ABBREV   sec0(1) ipdsnum ipdstemllen ipdstmp(1) ipdstmp(2) ipdstmp(10)*
*ipdstmp(10),ipdstmp(12) ipdstmp(13) ipdstmp(14) ipdstmp(15)ipdstmp(24)*
*idrstmp(3)                                                            *
------------------------------------------------------------------------
        APCP    0   8  30   1     8    1   0    0   255   0    0   1   4